Specification of Ultrasonic flaw detector USE-60FR Brand Adelix Turkey
Force gauge
Ultrasonic flaw detector USE-60FR
USE-60FR Ultrasonic flaw detector The revolutionary Ultrasonic flaw detector in phased arrays for the first time combines the use of conventional headlight transducers with mathematical signal processing using the SAFT method.
Technicial Specifications
PAA type used: any conventional 16-Channel phased antenna arrays
Working aperture setting: 4, 8 and 16 simultaneous working elements
Adjustment of scanning pitch by angle: 0.3 to 2 degrees
Scanning: – min.: 0-5 mm-max 0-600 mm. -0.1, 1, 5, 10 mm increments
Mode: S-scan (sector scan), L-scan (linear scan)
Speed range: 100-10,000 m/s
Probing pulse: a radio pulse with an amplitude of 50 V, with an adjustable number of periods (0.5-5)
Frequency of PD repetitions: automatically adjusted depending on the set parameters
Amplifier: wideband: 0.1-20 MHz (-6 dB)
Gain control range: 80 dB, 0.5, 1, 2, 6 dB in increments
Additional switch + dB: + 6 dB
Temporary sensitivity adjustment (GHA): linear, steepness up to 10 dB/ms
Angular sensitivity adjustment (AHA): 10-point correction
Detection: A-scan, B-scan, C-scan, D-scan, S-scan, L-scan, TOFD
Control zones: adjustable rectangular control zone
Automatic fault Alarm (OHA): light, sound
Self-diagnostic capabilities: full diagnosis of all elements of the transducer, construction of sensitivity propagation diagrams, diagnosis of switch operation
Display: high contrast colour, TFT 640 x 480 pixels, (130 x 100 mm).
A-signal:
– 480 x 300 points in standard mode
– 640×480 in full screen mode
Memory: A-signal with 200 settings 1000 monitoring protocols
Interface: USB
Converter Connectors: 2 x Lemo00, 1 x Lemo 16
Battery: Li-ion 10.8 V, 5000 mAh
Working time: at least 10 hours working from internal battery
External power supply: 220 V AC power supply
Supply voltage: 15 V / 2.5 a DC
Operating temperature range: -30°C to +55°C
Dimension (H x W x D): 200mm x 225mm x 80mm
Weight: 1.4 kg with batteries